Make a roughness requirement reproducible by identifying the functional land, trace direction and reporting settings.
Point the callout to the actual contact band rather than the entire shaft. A lead-in chamfer, transition or runout groove may have a different function. Where the contact band is narrow, check that the intended measuring path can stay within the surface to which the requirement applies.
Name the roughness parameter and applicable specification, and agree on trace direction and evaluation settings with inspection. A trace along the machining marks need not give the same result as a trace crossing them. Where defects or directional lead are also important, define their acceptance separately instead of expecting a single roughness number to describe them.
Technical reference: Mitutoyo’s guide to surface roughness measurement.